¼ò½é
MGate 5105-MB-EIPÊÇÒ»¿î¹¤Òµ¼¶ÒÔÌ«ÍøÍø¹Ø£¬ÎªModbus RTU/ASCII/TCPºÍEtherNet/IPÖ®¼ä½¨Á¢Í¨Ñ¶Á¬½Ó¡£ÎªÁ˽«ÏÖÓеÄModbusÉ豸ÕûºÏÔÚEtherNet/IPÍøÂçÉÏ£¬¿ÉʹÓÃMGate 5105-MB-EIP×÷ΪModbusÖ÷Õ¾»ò´ÓÕ¾À´ËѼ¯Êý¾Ý£¬²¢ÓëEtherNet/IPÉ豸½øÐÐÊý¾Ý½»»»¡£*еĽ»»»Êý¾Ý¿É±»´æ´¢ÔÚÍø¹ØÖУ¬È»ºóÍø¹Ø½«´æ´¢µÄModbusÊý¾Ýת»»³É EtherNet/IPÊý¾Ý°ü£¬ÕâÑù£¬EtherNet /IPɨÃèÆ÷¾Í¿ÉÒÔ¼à¿ØModbusÉ豸ÁË¡£
ͨ¹ýmicroSD¿¨½øÐÐÅäÖñ¸·Ý
MGa te 510 5 -MB-EIPÅäÓÐÒ»¸ömicroSD¿¨²å²Û¡£microSD¿¨¿ÉÒÔÓÃÀ´±¸·ÝϵͳÅäÖúÍϵͳÈÕÖ¾£¬Ò²¿É·½±ãµÄ½«ÏàͬµÄÅäÖÃÐÅÏ¢¸´ÖƵ½¼¸¸öMGate 5105-MP-EIPÖС£µ±ÏµÍ³ÖØÆðʱ£¬MGate×ÔÉí¾Í¿ÉÒÔ¸´ÖÆ´æ´¢ÔÚmicroSD¿¨ÖеÄÅäÖÃÎļþÐÅÏ¢¡£
ͨ¹ýWeb Console£¬ÇáËɽøÐÐÅäÖú͹ÊÕÏÅųý
MGate 5105-MB-EIP»¹ÌṩÁËÒ»¸öWeb console£¬¿ÉÇáËɽøÐÐϵͳÅäÖã¬ÎÞÐè°²×°¶îÍâµÄ¹¤¾ß¡£Ö»ÐèÒÔ¹ÜÀíÔ±Éí·ÝµÇ½£¬¾Í¿É·ÃÎÊËùÓÐÉèÖã»»ò×÷Ϊһ°ãÓû§¾ßÓÐÖ»¶ÁȨÏÞ¡£³ýÁË»ù±¾ÐÒéµÄÅäÖã¬Ä㻹¿ÉÒÔʹÓÃWeb consoleÀ´¼à¿ØI/OÊý¾ÝµÄÊýÖµºÍת»»Çé¿ö¡£ÌرðµÄÊÇ£¬I/OÊý¾ÝÓ³É䣨I/O Data Mapping£©¿ÉÒÔÏÔʾÁ½ÖÖÐÒéµÄÊý¾ÝµØÖ·£¬Ò»ÖÖÊÇÔÚÍø¹ØÄÚ´æÖеÄÐÒ飬ÁíÒ»ÖÖÊÇÔÚI/OÊý¾ÝÊÓͼ£¨I/O Data View£©ÖеÄÐÒ飬´Ó¶ø±ãÓÚÄú¸ú×ÙÍøÂç½ÚµãÖеÄÊý¾ÝÖµ¡£²»½öÈç´Ë£¬ÎªÃ¿¸öÐÒé½øÐÐÕï¶ÏºÍͨѶ·ÖÎö£¬¿ÉÌṩÌṩÓÐÓõÄÐÅÏ¢£¬±ãÓÚ½øÐйÊÕÏÅųý¡£
ÈßÓàµçÔ´ÊäÈë
MGate 5105-MB-EIP¾ßÓÐË«µçÔ´ÊäÈ룬¿ÉÌṩ¸ü¸ßµÄ¿É¿¿ÐÔ¡£¿ÉͬʱÁ¬½Óµ½2¸öÖ±Á÷µçÔ´£¬¼´Ê¹Ò»¸öµçÔ´³öÏÖ¹ÊÕÏ£¬Ò²Äܱ£Ö¤ÏµÍ³Á¬ÐøÔËÐС£Moxa»á¸ù¾Ý²»Í¬¹¤ÒµÓ¦ÓÃÐèÇó£¬ÎªÄúÌṩ¸ü¸ß¼¶±ð¿É¿¿ÐԵĽø½×¼¶Modbusת EtherNet/IPÍø¹Ø¡£
ÒÔÌ«ÍøÐÒ飺EtherNet/IP£¬Modbus TCP
¶Ë¿ÚÊýÁ¿£º2¸ö£¨ÒÔÌ«Íø¼¶Áª£©
ËÙÂÊ£º10/100 Mbps£¬Auto MDI/MDIX
Á¬½ÓÍ·£º8-pin RJ45
µç´Å¸ôÀë±£»¤£ºÄÚ½¨1.5 kV
EtherNet/IPÀàÐÍ£ºÊÊÅäÆ÷£¬É¨ÃèÆ÷
Ö§³ÖCIP¶ÔÏó£ºIdentity£¬Message Router£¬Assembly£¬
Connection Manager£¬TCP/IP interface£¬Ethernet link£¬
Port
*´óÁ¬½ÓÊýÁ¿£º
MGate×÷ΪÊÊÅäÆ÷£º16¸öÖ»¶ÁÁ¬½Ó£¬1¸ö¿É¶Á/¿ÉдÁ¬½Ó
MGate×÷ΪɨÃèÆ÷£º100¸öÁ¬½Ó
*´ó×ÜI/OÊý¾Ý´óС£º
ÊäÈ룺2048 bytes (496 bytes per connection)
Êä³ö£º2048 bytes (496 bytes per connection)
ModbusÖ§³Ö¹¦ÄÜ£º1£¬2£¬3£¬4£¬5£¬6£¬15£¬16£¬23
*´óÃüÁîÊýÁ¿£º100
*´óÁ¬½ÓÊýÁ¾£º
MGate×÷ΪModbus TCP Master£º32¸öÁ¬½Ó
MGate×÷ΪModbus TCP Slave£º16¸öÁ¬½Ó
*´ó×ÜI/OÊý¾Ý´óС£º
ÊäÈ룺2048 bytes
Êä³ö£º2048 bytes
Modbus´®¿Ú½çÃæÐÒ飺Modbus RTU/ASCII
¶Ë¿ÚÊýÁ¿£º1
´®¿Ú±ê×¼£ºRS-232/422/485£¬software selectable
Á¬½ÓÍ·£ºDB9 male
¸ôÀë±£»¤£º2 kV (built-in)
RS-485Êý¾ÝÁ÷Ïò¿ØÖÆ£º ADDC® (automatic data
direction control)
RS-485ÉÏÀ/ÏÂÀµç×裺1 KΩ£¬150 KΩ
RS-485Öն˵ç×裺120 Ω
Êý¾Ýλ£º5£¬6£¬7£¬8
ֹͣλ£º1£¬1.5£¬2
УÑéλ£ºNone£¬Even£¬Odd£¬Space£¬Mark
Á÷¿Ø£ºRTS/CTS£¬RTS Toggle
²¨ÌØÂÊ£º50 bps ~ 921.6 Kbps
Íⲿ´æ´¢Çý¶¯½çÃæ£ºmicroSD
±ê×¼£ºSDHC v2.0
´®¿ÚÐźÅRS-232£ºTxD£¬RxD£¬RTS£¬CTS£¬DTR£¬DSR£¬DCD£¬GND
RS-422£ºTx+£¬Tx-£¬Rx+£¬Rx-£¬GND
RS-485-4w£ºTx+£¬Tx-£¬Rx+£¬Rx-£¬GND
RS-485-2w£ºData+£¬Data-£¬GND
Èí¼þSoftware²Ù×÷ģʽ£ºEtherNet/IPÊÊÅäÆ÷/ɨÃèÆ÷£¬Modbus RTU/
ASCII/TCP Master/Slave
ÅäÖÃÑ¡ÏWeb console£¬Windows utility£¬serial console
¹¤¾ß£ºMGate Manager for Windows 2000/XP/2003/
Vista/Server 2008/7/8 (x86/x64)£¬Windows Server 2008
R2/2012 (x64)
»úÐµÌØÐÔÍâ¿Ç£º½ðÊô (IP30)
ÖØÁ¿£º507 g
³ß´ç£º36 x 105 x 140 mm (1.42 x 4.13 x 5.51 in)
¹¤×÷»·¾³¹¤×÷ζȣº
±ê×¼Ðͺţº0 ~ 60 °C (32 ~ 140 °F)
¿íÎÂÐͺţº-40 ~ 75 °C (-40 ~ 167 °F)
´æ´¢Î¶ȣº-40 ~ 85 °C (-40 ~ 185 °F)
Ïà¶Ôʪ¶È£º5 ~ 95% (non-condensing)
º£°Î¸ß¶È£º*¸ß¿É´ï2000 m
×¢Ò⣺Èç¹ûÄúÓиü¸ßº£°Î¸ß¶ÈµÄÐèÇó£¬ÇëËæÊ±ÓëÎÒÃÇÁªÏµ¡£
µçÔ´ÐèÇóÊäÈëµçѹ£º12 ~ 48 VDC
Á¬½ÓÀàÐÍ£ºTerminal block
µçÔ´¹¦ºÄ£º455 mA @ 12 VDC£¬125 mA @ 48 VDC
°²¹æÈÏÖ¤Safety: UL 508£¬EN 60950-1
EMC: CE£¬FCC
EMI: EN 55022 Class A£¬FCC Part 15 Subpart B Class A
EMS:EN 55024£¬EN 61000-4-2 (ESD) Level 4£¬ EN
61000-4-3 (RS) Level 3£¬EN 61000-4-4 (EFT) Level 4£¬EN
61000-4-5 (Surge) Level 3£¬EN 61000-4-6 (CS) Level 3£¬
EN 61000-4-8£¬(PFMF) Level 3
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
¿É¿¿ÐÔMTBF (ƽ¾ùÎÞ¹ÊÕÏʱ¼ä)£º513£¬139 hrs
±£ÐÞ±£ÐÞÆÚ£º5Äê