¼ò½é
EDS-510EǧÕ×ÒÔÌ«Íø½»»»»úÊÇרΪÑÏ¿ÁµÄ¹Ø¼üÈÎÎñÓ¦ÓöøÉè¼ÆµÄ£¬ÀýÈ繤³§×Ô¶¯»¯£¬ITS¼°¹ý³Ì¿ØÖÆ¡£3¸öǧÕ×ÒÔÌ«Íø¿ÚÓµÓм«Ç¿µÄÁé»î¶ÈÀ´½¨ÔìÒ»¸öǧÕ×ÈßÓà»·Íø¼°Ò»¸öǧÕ×ÉÏÐÐÁ´Â·¡£EDS-510E²ÉÓÃUSB½Ó¿ÚΪ½»»»»úÌṩÅäÖã¬ÏµÍ³Îļþ±¸·ÝºÍ·À»ðǽÉý¼¶À´Ê¹¹ÜÀí¸ü¼òµ¥¡£
ÌØµãºÍÓÅÊÆ
- ÃüÁîÐнçÃæ£¨CLI£©£¬¿É¿ìËÙÅäÖÃÖ÷ÒªÍø¹Ü¹¦ÄÜ
- »ñµÃIPv6 Ready±êÖ¾£¨IPv6±ê־ίԱ»áÈÏÖ¤£©
- IEEE 1588 PTP V2£¨¾«ÃÜʱ¼äÐÒ飩£¬Ö§³Ö¾«È·µÄÍøÂçʱ¼äͬ²½
- DHCP Opition 82£¬ÓÃÓÚÒÔ²»Í¬²ßÂÔ·ÖÅäIPµØÖ·
- Ö§³ÖEtherNet/IP£¬PROFINETºÍModbus/TCP¹¤ÒµÒÔÌ«ÍøÐÒ飬ΪÉ豸×ö¹ÜÀí¼°¼à¿Ø
- Ö§³ÖTurbo Ring£¬Turbo Chain£¨×ÔÓúʱ¼ä < 20 ms @ 250̨½»»»»ú£©£¬RSTP/STPºÍMSTPÍøÂçÈßÓà
- IGMP SnoopingºÍGMRP¹ýÂË×é²¥·â°ü
- Ö§³ÖPort-based VLAN£¬IEEE 802.1Q VLANºÍGVRP ÐÒ飬¼òÒ×ÍøÂç¹æ»®
- Ö§³ÖQoS£¨IEEE802.1p/1Q£©ºÍTOS/Dif fServ£¬Ôö¼ÓÍø
- Ö§³ÖÁ´Â·¾ÛºÏ£¬*´ó»¯ÀûÓôø¿í
- Ö§³ÖRADIUS, TACACS+, SNMPv3, IEEE 802.1X, HTTPSºÍSSH£¬¼ÓÇ¿ÍøÂ簲ȫÐÔ
- Ö§³ÖSNMPv1/v2c/v3 ²»Í¬µÈ¼¶µÄÍøÂç¹ÜÀíÐÒé
- ²ÉÓÃRMONÓÐЧÌáÉýÍøÂç¼à²âºÍÔ¤²âÄÜÁ¦
- Ö§³Ö´ø¿í¹ÜÀí£¬È·±£ÍøÂçÎȶ¨ÐÔ
- Ö§³Ö»ùÓÚMACµØÖ·µÄ¶Ë¿ÚËø¶¨£¬·ÀÖ¹·Ç·¨ÈëÇÖ
- ͨ¹ýE-mailºÍ¼ÌµçÆ÷Êä³ö×Ô¶¯±¨¸æÒâÍâʼþ
- ͨ¹ýÍøÒ³ä¯ÀÀÆ÷£¬Te l n e t /S e r i a l c o n s o l e , CL I , MXconfigºÍABC0-2×Ô¶¯±¸·ÝÅäÖÃÆ÷
- ¼¼Êõ²ÎÊý±ê×¼
IEEE 802.3ÊÊÓÃÓÚ10BaseT
IEEE 802.3uÊÊÓÃÓÚ100BaseT(X) and 100BaseFX
IEEE 802.3abÊÊÓÃÓÚ1000BaseT(X)
IEEE 802.3zÊÊÓÃÓÚ1000BaseX
IEEE 802.3xÊÊÓÃÓÚFlow Control
IEEE 802.1D-2004ÊÊÓÃÓÚSpanning Tree Protocol
IEEE 802.1wÊÊÓÃÓÚRapid STP
IEEE 802.1sÊÊÓÃÓÚMultiple Spanning Tree Protocol
IEEE 802.1QÊÊÓÃÓÚVLAN Tagging
IEEE 802.1pÊÊÓÃÓÚClass of Service
IEEE 802.1XÊÊÓÃÓÚAuthentication
IEEE 802.3adÊÊÓÃÓÚPort Trunk with LACP
ÐÒ飺IGMPv1/v2/v3, GMRP, GVRP, SNMPv1/v2c/v3,
DHCP Server/Client, BootP, TFTP, SNTP, SMTP, RARP,
RMON, HTTP, HTTPS, Telnet, Syslog, DHCP Option
66/67/82, SSH, SNMP Inform, EtherNet/IP, PROFINET,
Modbus/TCP, LLDP, IEEE 1588 PTP V2, IPv6, NTP
Server/Client
MIB: MIB-II, Ethernet-Like MIB, P-BRIDGE MIB,
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB
Group 1, 2, 3, 9
Á÷Á¿¿ØÖÆ£ºIEEE 802.3x flow control, back pressure flow
control
½»»»»úÊôÐÔÓÅÏȼ¶¶ÓÁУº4
*¶à¿ÉÓÃVLANsÊý£º64
VLAN ID·¶Î§£ºVID 1~4094
IGMP×飺256
MACµØÖ·±í´óС£º8K
·â°ü»º³åÇø´óС£º1 Mbit
½Ó¿Ú¹âÏ˿ڣº100/100BaseSFP²å²Û
RJ45¿Ú£º10/100BaseT(X)»ò10/100/1000BaseT(X)×ÔÕì²â
USB¿Ú£ºUSB console¿Ú£¨BÀàÐÍÁ¬½ÓÍ·£©
°´Å¥£ºÖØÖð´Å¥
DIP¿ª¹Ø£ºTurbo Ring, Master, Coupler, Reserve
LEDָʾµÆ£ºPWR1, PWR2, FAULT, STATE, 10/100M (TP
port), 100/1000M (Gigabit port), MSTR/HEAD, CPLR/TAIL
±¨¾¯Í¨Öª£º1¸ö¼ÌµçÆ÷Êä³ö£¬µçÁ÷¸ºÔØÄÜÁ¦1 A@ 24 VDC
Êý×ÖÊäÈ룺Á½Â·ÊäÈ룬µç×Ó¸ôÀ룬¹²µØ
• “״̬1”+13 to +30V
• -30 to +3V for state “0”
• Max. input current: 8 mA
µçÔ´ÐèÇóÊäÈëµçѹ£º12/24/48/-48VDC£¬Ë«ÈßÓàÊäÈë
ÊäÈëµçÁ÷£º
EDS-510E: 0.68 A @ 24 V
¹ýÔØ±£»¤£ºÌṩ
Á¬½Ó£º2¸ö¿É²å°ÎµÄ4Õë½ÓÏß¶Ë×Ó
·´½Ó±£»¤£ºÌṩ
»úÐµÌØÐÔÍâ¿Ç£º½ðÊô£¬IP30·À»¤µÈ¼¶
³ß´ç£º79.2 x 135 x 116 mm (3.12 x 5.31 x 4.57 in)
ÖØÁ¿£º1690g
°²×°£ºµ¼¹ìʽ»òÕß±Ú¹Òʽ°²×°£¨¿ÉÑ¡Ì×¼þ£©
¹¤×÷»·¾³¹¤×÷ζȣº
±ê×¼Ðͺţº-10 ~ 60 °C (14 ~ 140 °F)
¿íÎÂÐͺţº-40 ~ 75 °C (-40 ~ 167 °F)
´¢´æÎ¶ȣº-40 ~ 85 °C (-40 ~ 185 °F)
Ïà¶Ôʪ¶È£º5 ~ 95% (ÎÞÄý¶)
°²¹æÈÏÖ¤Safety: UL 508
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 4, EN 61000-4-3 (RS) Level 3,
EN 61000-4-4 (EFT) Level 4, EN 61000-4-5 (Surge) Level 4,
EN 61000-4-6 (CS) Level 3, EN 61000-4-8, IEEE 1613
Traffic Control: NEMA TS2
Rail Traffic: EN 50121-4
Shock: IEC 60068-2-27
Freefall: IEC 60068-2-32
Vibration: IEC 60068-2-6
×¢£ºÇëµÇÈëMoxaÍøÕ¾£¬»ñÈ¡*ÐÂÈÏÖ¤ÐÅÏ¢¡£
MTBF £¨Æ½¾ùÎÞ¹ÊÕÏʱ¼ä£©Ê±¼ä£º723,532 hrs
Êý¾Ý¿â£ºTelcordia (Bellcore), GB
±£ÐÞ±£ÐÞÆÚ£º5Äê